Midnight Blue researcher Carlo Meijer found six pre-authentication remote code execution zero-days in the Danfoss AK-SM800A refrigeration controller. He found them in under an hour of manual firmware review. All firmware versions up to and including 5.3.2 are affected.

Attacks on internet-exposed Danfoss and Copeland controllers began in France on October 11. They continued in a second wave on November 2. Attackers triggered defrost cycles, spoiled tens of millions of euros of food and, in some cases, started fires.

The campaign has grown serious enough that CISA and the FBI warned of attacks on industrial refrigeration and cold chain monitoring systems , which shows the problem reaches well beyond Europe.

Vulnerabilities in Danfoss Refrigeration Controllers

Earlier research had already exposed weaknesses in these products. Synacktiv, Claroty and DIVD documented the “code-of-the-day” authentication bypass (CVE-2025-41450), OS command injection (CVE-2023-25915, CVE-2025-41451) and path traversal (CVE-2023-25914). Public proof-of-concept exploits appeared within 48 hours of the French attacks. Censys still shows hundreds of exposed Danfoss systems and more than 1,000 Copeland and Dixell units.

Meijer emulated the firmware in user space using QEMU and focused on the web task within the sm_app. This monolithic binary handles most device functions.

The device operates on Danux, a custom Yocto-based Linux distribution, running on an i.MX6 processor. There are hundreds of unsafe `strcpy` calls located in unauthenticated handlers. The binaries do not utilize stack canaries or Position Independent Executables (PIE), and the vulnerable application operates with root privileges.

A single crafted request sent to an unauthenticated CGI endpoint can cause a segmentation fault. At least five similar vulnerabilities have been identified in a small segment of code.

Additionally, a sixth vulnerability was found in sm_fcgi_app, which handles the “strict” session control mode that Danfoss set as the default starting with version 4.0.

According to the Midnight Blue , this flaw allows for pre-authentication code execution even when strict mode is enabled. Specific endpoint details are being withheld due to the ongoing coordinated disclosure with Danfoss, and CVE identifiers are pending.

The impact goes beyond defrost sabotage. The controllers do not use the i.MX6 secure boot features, so an attacker with root could plant an implant that survives a factory reset or firmware update.

An attacker could also wipe flash memory or push malformed firmware to brick devices, forcing physical replacement and leaving freezers unavailable for days. The researchers compare this to the December 2025 attack on the Polish electric grid.

The findings also undercut the value of compliance badges. Danfoss business units hold IEC 62443-4-1 certification for secure product development, yet the code lacks basic exploit mitigations. The problem is not unique to Danfoss, as shown by the 23 vulnerabilities recently disclosed in Copeland XWEB Pro controllers that could give attackers root access.

The researchers argue that patching and strict session control are a poor use of limited security resources. Asset owners should first find every exposed controller, including those behind system integrator 4G modems.

They should then restrict management access to a VPN, a private APN, or tightly scoped IP allowlists. CERT-FR treats allowlisting as an interim measure because of configuration drift.

Give your SOC the alert context on the latest threats to stop incidents quickly -> Integrate Threat Intel from 16K SOCs :

Artificial Intelligence

Cyber security Course

Cyber Security Resources

Cybersecurity

Information Gathering

Information Security Risks

OpenAI Launches Advanced AI Cybersecurity Tools for Automated Penetration Testing and Vulnerability Research

Chinese-Speaking Hackers Weaponize Cairn AI Framework to Breach Semiconductor and Defense Organizations

11 Vulnerability Scanners: The 2026 Buyer’s Verdict Guide

11 AI Governance (AI TRiSM) Platforms: The 2026 Buyer’s Verdict Guide

StingyBasilisk APT Uses Windows Named Pipes to Control Malware and Evade Security Detection

Critical Red Hat Quay Vulnerability Allows Hackers to Hijack Private Container Registries