Dsa 2026 08 01
Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 Hybrid software
Advisory ID: DSA-2026-08-01
CVE numbers and CVSS scores CVE number: CVE-2026-15203 CVSS:9.3
CVE number: CVE-2026-15203
Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 software expose debug interfaces by default, allowing unauthorized access to internal data, uploading unsigned applications, and modifying firmware.
Affected products and services
Danfoss iC7-Automation SP prior to version 2025.3.3
Danfoss iC7-Marine prior to version 2025.8.19
Danfoss iC7-Hybrid prior to version 2025.10.300845
Vulnerability description
Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms.
iC7-Automation SP: (Release 2026.2.5-26A)
iC7-Marine: (Release 2026.6.30-GR4.4)
iC7-Hybrid: (Release 2026.7.2-GR4.5)
Credits (if opted in)
18 September, 2026: Publication
The full story